Kesselhaus

Hauptbild Name Hersteller Typ Größe Kapazität

Diesel - Notstromaggregat 350 kvA

Diesel-Notstromaggregat mit 350 kVA Leistung

 

350 kVA

Dampfkessel - 3 Stück

inkl. diverser Kohlezufuhr- und Schlackeaustragtechnik

max. zul. Temp: 435 / 300 / 220 Grad Celsius

max. zul Druck: 36 / 13 / 13 Bar

Hezizfläche 1131,00 / 329,00 / 329,00

Gas turbine plant including generator & waste heat boiler

Gasturbine

Manufacturer: Allison /Rolls Royce

Type: 501 KB 7

year of construction: 2000

Electrical output: 4.200 kWel

Speed: 14.944min.-1 50Hz

Fuel: natural Gas H

Design temperature: 15°C

Turbine inlet temperature: 665°C (1.229°F)

 

Generator (in the package)

Manufacturer: Leroy Somer

Type: 3 phase synchronous

Year of manufacturing: 2000

Rated power: 5.450 kVA

Speed: 1.500 min-1

Cos phi: 0.98 (nominal 0.8)

Frequency: 50 Hz

Rated voltage: 10.5 kV

Rated current:299.7 A

 

Waste heat boiler behind the GT - incl. chimney

Type of smoke tube boiler with ECO

Manufacturer: Jumey

Year of construction: 2000

Fuel: Flue gases from a turbine and additional firing Eclipse

Nominal steam output: 18.5 t/h

Nominal FD pressure: 14.5 bar (g)

Max. permissible FD pressure: 18 bar (g)

Allison / Rolls Royce 501 KB 7

Gas turbine plant including generator & waste heat boiler

Gasturbine

Manufacturer: Solar Turbines

Type: Centaur 50 SoLONox

year of construction: 1997

Electrical output: 4.200 kWel

Speed: 14.944min.-1 50H

Fuel: natural Gas H

Design temperature: 15°C

Turbine inlet temperature: 665°C (1.229°F)

 

Generator (in the package)

Manufacturer: ABB

Type: 3 phase synchronous

Year of manufacturing: 1997

Rated power: 5.450 kVA

Speed: 1.500 rpm

Cos phi: 0.98 (nominal 0.8)

Frequency: 50 Hz

Rated voltage: 10.5 kV

 

Waste heat boiler behind the GT - incl. chimney

Type of smoke tube boiler with ECO

Manufacturer: Koethen

Year of construction: 2008

Fuel: Flue gases from a turbine

Perm. heat output: 7.633 kW

Nominal steam output: 13 t/h

Nominal FD pressure: 14.5 bar (g)

Max. permissible FD pressure: 18 bar (g)

FD temperature: 210°C

Water contents: 1,475l

Heating surface: 2.577 m²

Solar Turbines Centaur 50 SoLoNox

Gas turbine plant including generator & waste heat boiler4600 kw

Gasturbine

year of construction: 1990 es

Electrical output: 4.600 kWel

Speed: 14.944min.-1 50Hz

Fuel: natural Gas H

Turbine inlet temperature: 665°C (1.229°F)

 

Generator (in the package)

Manufacturer: ABB

Type: 3 phase synchronous

Year of manufacturing: 1990 ies

Rated power: 6.000 kVA

Speed: 1.500 rpm

Cos phi: 0.98 (nominal 0.8)

Frequency: 50 Hz

Rated voltage: 10.5 kV

 

Dampfkessel

Second hand / used boiler Pillard

Conception: water rolls

Boiler stamps: 48 bar eff.

Outlet pressure superheater: 40 bar eff.

Overheating temperature: 440°C

Feed water temperature: 105°C

Combustible: natural gas, fuel-oil

Heating surface boiler: 487 m²

Heating surface superheater: 108 m²

Water volume: 10,4 m³

Steam volume: 3,9 m³

with control system Andover controls AC256M plus

Pillard GRX

Diesel Generator 2500kW

Unused 2500KW DIESEL GENESET x 3UNITS

Type: Package type (on the base plate)

 

Engine

make: MTU(Germany)

Year: 2011

 

Alternator

make: Hyundai(Korea)

Year: 2011

Fuel: Diesel

 

Engine specification:

Engine type:4 stroke, water coolled

Aspiration type:Terbo charger,Intelcooler

Power:2740kWh

RPM:1800

Number of cylinders:20

Cylinder configuration:90 Vee

Bore:170mm

Stroke:210mm

Displacement:95.4liter

Compression ratio:16.4:1

Combustion system:Direct injection

Mean effective pressure:19.2bar

Mean piston speed:12.6m/s

Governor type:ADEC

Cooling system:Radiator

 

Alternator specification:

Make:Hyundai (Korea)

Year:2011

Rated capacity:2500KW

Factor:0.8

Rated voltage:440V

Rated current:4100.5 A

RPM:1800

HZ:60

Brushless self exciting type

Poles:4

3Phases

Bearing:anti-friction bearing

Insullation class:F

Voltage adjustment range:plus minus 10%

Cooling type:air cooled

 

Engine Dimension:

3586 mm x1613mm x2077mm

Weight:9864kg

 

Technical Data:

1.Combustion air/Exaust gas

-Combustion air volume flow:225m3/sec

-Exaust temperature after turbocharger:455

-Exaust back pressure(desgn/limit value:30/85 mbar

 

2.Fuel system

-Fuel specification:EN590,Grade Nr,

1/2-D(ASTM D975)

Class A2(BS 2869)

-Fuel consumption:

100% load:197g/kWh

75% load: 210g/kWh

50% load: 225g/kWh

25% load: 259g/kWh

 

 

3.Lube oil :API CG-4 and ACEA

E2-96, SE 15W-40

 

4.Coolant system(High temperature)

-Coolant water capacity:205liter

-Coolant temperature(Engine outlet):100

-Coolant flow rate:94m3/h

 

5.Coolant system(Low temperature)

-Coolant water capacity(Intercooler):55liter

-Coolant temperature(Intercooler inlet):55

-Coolant flow rate:94m3/h

 

6.Noise

-Engine surface noise:115dB(A)

-Undamped exaust gas noise:128dB(A)

 

7.Engine protection(Alarm/Shutdown)

-Cooling water over temperature:102/104

-Intercooler over temperature:75

-Lubrication oil low pressure:3.9bar/3.6bar

-Lubrication over temperature:99/101

-Fuel over temperature:100

-Engine over speed: / 1950rpm

MTU / Hyundai Package Type

Dampfturbine und Generator

Second hand Steam Turbine and Generator:

1) Steam Turbine:

manufacturer: Siemens-Schuckert

year of manufacturing: 1986

steam temperature: 435 / 450°C

steam pressure: 33 / 45 kg

power: 1950 / 2300 Kw

8000 U/min

2) Generator:

manufacturer: Simens-Schuckert

4000KVA

1500 U/min

50 Hz

Siemens 4000 KvA

Müllverbrennungsanlage Kessel

Burning capacity: 2.000 t/year Reject

Expected heating fuel value 12.000 kJ/kg

Burning capacity: 300 kg/h

Steam production: 1 t/h

Auxiliary fuel: Gas

Automatical / manual feeding

Automatical ash disposal

Dry smoke gas cleaning

 

 

German manufacturer Reject incinerator for steam 1 t steam/h